Uncertainty Quantification of Methods Used to Measure Methane Emissions of 1 g CH4 h−1

  • Stuart N. Riddick
  • , Mercy Mbua
  • , John C. Riddick
  • , Cade Houlihan
  • , Anna L. Hodshire
  • , Daniel J. Zimmerle

Resultado de pesquisarevisão de pares

7 Citações (Scopus)

Resumo

The recent interest in measuring methane (CH4) emissions from abandoned oil and gas wells has resulted in five methods being typically used. In line with the US Federal Orphaned Wells Program’s (FOWP) guidelines and the American Carbon Registry’s (ACR) protocols, quantification methods must be able to measure minimum emissions of 1 g of CH4 h−1 to within ±20%. To investigate if the methods meet the required standard, dynamic chambers, a Hi-Flow (HF) sampler, and a Gaussian plume (GP)-based approach were all used to quantify a controlled emission (Qav; g h−1) of 1 g of CH4 h−1. After triplicate experiments, the average accuracy (Ar; %) and the upper (Uu; %) and lower (Ul; %) uncertainty bounds of all methods were calculated. Two dynamic chambers were used, one following the ACR guidelines, and a second “mobile” chamber made from lightweight materials that could be constructed around a source of emission on a well head. The average emission calculated from the measurements made using the dynamic chamber (Qav = 1.01 g CH4 h−1, Ar = +0.9%), the mobile chamber (Qav = 0.99 g CH4 h−1, Ar = −1.4%), the GP approach (Qav = 0.97 g CH4 h−1, Ar = −2.6%), and the HF sampler (Qav = 1.02 g CH4 h−1, Ar = +2.2%) were all within ±3% of 1 g of CH4 h−1 and met the requirements of the FOWP and ACR protocols. The results also suggest that the individual measurements made using the dynamic chamber can quantify emissions of 1 g of CH4 h−1 to within ±6% irrespective of the design (material, number of parts, geometrical shape, and hose length), and changes to the construction or material specifications as defined via ACR make no discernible difference to the quantification uncertainty. Our tests show that a collapsible chamber can be easily constructed around the emission source on an abandoned well and be used to quantify emissions from abandoned wells in remote areas. To our knowledge, this is the first time that methods for measuring the CH4 emissions of 1 g of CH4 h−1 have been quantitively assessed against a known reference source and against each other.

Idioma originalEnglish
Número do artigo9246
RevistaSensors
Volume23
Número de emissão22
DOIs
Estado da publicaçãoPublished - 16 nov. 2023

Impressão digital

Mergulhe nos tópicos de investigação de “Uncertainty Quantification of Methods Used to Measure Methane Emissions of 1 g CH4 h−1“. Em conjunto formam uma impressão digital única.

Citar isto