The Bioganix in-vessel composting system at Leominster, UK, received 33 515 t of waste from January 2006 to December 2007, of which 9200 t was source-segregated biodegradable municipal waste (BMW). The process operated with a nominal in-vessel retention time of 4 days. Mass balances indicated 17·1% reduction (excluding reject materials). The process was estimated to consume 186 kWh/t of waste processed as electrical energy for static plant and a further 9·6 kWh as diesel for mobile plant. Taking into account transportation and application of the compost, the estimated consumption was ~560 kWh/t of waste processed, calculated as primary energy (including electrical conversion). 96·7% of this was for processing; transportation consumed 1·3% and application 2·0%. The mixed waste compost had a high nitrogen content but, for a typical source-segregated biodegradable municipal waste, the energy potentially offset from nitrogen fixation is likely to be considerably less than that used in processing.
Idioma originalEnglish
Título da publicação do anfitriãoProceedings of the Institution of Civil Engineers-Waste and Resource Management
EditoraICE Publishing Ltd.
Páginas151-159
Número de páginas9
Volume164
Edição3
DOIs
Estado da publicaçãoPublished - ago. 2011

ODS da ONU

Este resultado contribui para o(s) seguinte(s) Objetivo(s) de Desenvolvimento Sustentável

  1. Sustainable cities and communities
    Sustainable cities and communities
  2. Responsible consumption and production
    Responsible consumption and production

Impressão digital

Mergulhe nos tópicos de investigação de “Mass and energy balance for a rotating-drum composting plant“. Em conjunto formam uma impressão digital única.

Citar isto