Resumen
An automatic interferometer fringe tracking system has been developed,
implemented, and tested at the Infrared Optical Telescope Array (IOTA)
Observatory at Mount Hopkins, Arizona. The system can minimize the
optical path differences (OPDs) for all three baselines of the Michelson
stellar interferometer at IOTA. Based on sliding window discrete
Fourier-transform (DFT) calculations that were optimized for
computational efficiency and robustness to atmospheric disturbances, the
algorithm has also been tested extensively on offline data. Implemented
in ANSI C on the 266 MHz PowerPC processor running the VxWorks real-time
operating system, the algorithm runs in approximately 2.0 milliseconds
per scan (including all three interferograms), using the science camera
and piezo scanners to measure and correct the OPDs. The adaptive
DFT-based tracking algorithm should be applicable to other systems where
there is a need to detect or track a signal with an approximately
constant-frequency carrier pulse. One example of such an application
might be to the field of thin-film measurement by ellipsometry, using a
broadband light source and a Fourier-transform spectrometer to detect
the resulting fringe patterns.
| Idioma original | English |
|---|---|
| Número de artículo | 531501 |
| Páginas (desde-hasta) | 2559-2572 |
| Número de páginas | 14 |
| Publicación | EURASIP Journal on Applied Signal Processing |
| Volumen | 2005 |
| N.º | 15 |
| DOI | |
| Estado | Published - 14 sept 2005 |
Huella
Profundice en los temas de investigación de 'Adaptive DFT-Based Interferometer Fringe Tracking'. En conjunto forman una huella única.Citar esto
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver