ملخص
Aim
To assess the clinical performance and patient acceptance of HemaSpot™ blood collection devices as an alternative blood collection method.
Methods
Adult men and women with any type of diabetes, routinely carrying out self‐monitoring of blood glucose were recruited (n = 128). Participants provided a venous blood sample and prepared two HemaSpot dried blood spots, one at clinics and one at home. HbA1c analysis was by Tosoh G8 high‐performance liquid chromatography. Participants also completed a questionnaire.
Results
Strong linear relationships been HbA1c levels in dried blood spots and venous blood were observed and a linear model was fitted to the data. Time between dried blood spot preparation and testing did not impact the model. Participants were accepting of the approach: 69.2% would use this system if available and 60.7% would be more likely to use this system than going to their general practitioner.
Conclusions
The combination of a robust desiccating dried blood spot device, home sample preparation and return by post produces HbA1c data that support the use of a time‐independent linear calibration of dried blood spot to venous blood HbA1c. A robust remote sample collection service would be valuable to people living with diabetes in urban areas who are working or house‐bound as well as those living in remote or rural locations.
To assess the clinical performance and patient acceptance of HemaSpot™ blood collection devices as an alternative blood collection method.
Methods
Adult men and women with any type of diabetes, routinely carrying out self‐monitoring of blood glucose were recruited (n = 128). Participants provided a venous blood sample and prepared two HemaSpot dried blood spots, one at clinics and one at home. HbA1c analysis was by Tosoh G8 high‐performance liquid chromatography. Participants also completed a questionnaire.
Results
Strong linear relationships been HbA1c levels in dried blood spots and venous blood were observed and a linear model was fitted to the data. Time between dried blood spot preparation and testing did not impact the model. Participants were accepting of the approach: 69.2% would use this system if available and 60.7% would be more likely to use this system than going to their general practitioner.
Conclusions
The combination of a robust desiccating dried blood spot device, home sample preparation and return by post produces HbA1c data that support the use of a time‐independent linear calibration of dried blood spot to venous blood HbA1c. A robust remote sample collection service would be valuable to people living with diabetes in urban areas who are working or house‐bound as well as those living in remote or rural locations.
| اللغة الأصلية | English |
|---|---|
| الصفحات (من إلى) | 1-8 |
| عدد الصفحات | 8 |
| دورية | Diabetic Medicine |
| تاريخ مبكر على الإنترنت | 16 أغسطس 2019 |
| المعرِّفات الرقمية للأشياء | |
| حالة النشر | Published - أكتوبر 2019 |
أهداف الأمم المتحدة للتنمية المستدامة
يساهم هذا المخرج في تحقيق أهداف الأمم المتحدة للتنمية المستدامة التالية (SDGs)
-
Good health and well being
بصمة
أدرس بدقة موضوعات البحث “HbA1c determination from HemaSpot? blood collection devices: comparison of home prepared dried blood spots with standard venous blood analysis'. فهما يشكلان معًا بصمة فريدة.قم بذكر هذا
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver